Spring Green Avalon – Civil Sitework & Utilities – Victoria, TX
What this bid is
Civil sitework and utility package for the Spring Green Avalon project on Spring Green Blvd. in Victoria, Texas 77901. The buyer is Spring Green Victoria Estate Ventures, LLC, working through Tekton Construction and Development Partners, and the owner is a special district type body in Texas. They want preliminary budget pricing and subcontractor pricing for the whole civil scope.
The scope covers clearing and mowing about 20 acres, excavation and grading, a sanitary sewer system with about 2,594 LF of 8" PVC main and 11 manholes, a water system with 6" and 8" C900 mains and fire hydrants, overland drainage with riprap, and paving with limestone base, prime and surface treatment, hot-mix asphalt, curb and gutter, sidewalks and curb ramps. There is also a SWPPP, staking, and a one-year maintenance bond the city requires at 25 percent of construction cost. Quantities are for reference only, and the notice asks bidders to do their own takeoff. It also notes work near an Energy Transfer pipeline easement.
Who should bid
Plumbing, Landscaping, Paving & Asphalt, Fencing, Concrete, Excavation & Grading, Irrigation, General Contracting, Site Utilities, Traffic & Striping, Hauling & Trucking, Surveying & Engineering contractors - the work is Victoria County, TX.
Deadline
30 October 2026, 6:00 PM CDT (3 days remaining - last confirmed 27 Oct)
How to submit
On the agency's own system, not on BusyBids. Open the official notice
As the agency published it
CIVIL / SITEWORK BID PACKAGE – SPRING GREEN AVALON Tekton Construction and Development Partners is requesting preliminary/budgetary and subcontractor pricing for the complete civil/sitework scope for the Spring Green Avalon project located on Spring Green Blvd., Victoria, Texas 77901. Pricing shall be based on the provided construction drawings and Estimated Quantities & Bid Sheet. Quantities are provided as a bidding reference only. Contractors shall perform their own takeoff and include all labor, materials, equipment, supervision, mobilization, testing, coordination, permits applicable to their trade, and incidentals necessary for a complete installation. GENERAL Storm Water Pollution Prevention Plan (SWPPP), including installation and maintenance of controls – 1 LS Construction staking – 1 LS. Urban Surveying will provide property-corner hubs one time; remaining construction staking shall be included by contractor. 1-year maintenance bond as required by the City of Victoria, based on 25% of construction cost. Mobilization, coordination, temporary facilities, safety measures, traffic control, cleanup and project closeout as applicable. SITE PREPARATION / EARTHWORK Clearing, mowing and mulching – approximately 20 AC Excavation and initial site grading – approximately 19,250 CY Degrass existing open ditch and adjacent spoil berm; use berm material to fill and compact existing ditch – approximately 1,000 CY Haul and spread excess excavated material generated from grading to adjacent commercial lots – approximately 7,250 CY Final site grading of disturbed areas – approximately 20 AC Seeding with Common Bermuda – approximately 20 AC Moisture conditioning, compaction, excavation, haul-off/import, grading and restoration necessary to achieve the proposed grades. SANITARY SEWER SYSTEM 8" PVC sanitary sewer main – approximately 2,594 LF 4' diameter sanitary sewer manholes, approximately 5'-12' deep – 11 EA 4" short-side single sanitary sewer services – 27 EA 4" long-side single sanitary sewer services – 28 EA Adjust rim elevation of existing storm sewer junction box – 1 EA Connect to existing sanitary manhole, including modification/removal of existing 12" stub-out and connection with proposed 8" sewer – 1 EA 8" sanitary sewer plug – 1 EA Trench excavation protection for sanitary sewer greater than 5' depth – approximately 2,594 LF Include excavation, bedding, pipe embedment, backfill, compaction, dewatering if required, testing, cleaning, connections and restoration. WATER SYSTEM 6" C900 PVC water main – approximately 300 LF 8" C900 PVC water main – approximately 2,185 LF Fire hydrant assemblies including 8"x6" tee, 6" lead, valve and hydrant – 5 EA 6" gate valve – 1 EA 8" gate valves – 9 EA 8"x8" tees – 5 EA 6" 45-degree bend – 1 EA 8" 45-degree bends – 3 EA 8" 22.5-degree bends – 2 EA 8"x6" reducer – 1 EA 8" plugs – 3 EA 2" Mueller automatic flush valve HG-100 Series – 1 EA Short-side single water services – 3 EA Long-side single water services – 7 EA Short-side double water services – 13 EA Long-side double water services – 8 EA 3/4" irrigation water service – 1 EA Irrigation conduit crossing at entrance, two 1-1/2" PVC conduits – 1 EA Locate and connect to existing 8" stub-out – 1 EA Include fittings, restraints/thrust protection, bedding, backfill, flushing, testing, disinfection, connections and restoration. DRAINAGE Overland drainage outfall including flume and curbing – approximately 3,235 SF 12" limestone rock riprap with filter fabric for erosion protection – approximately 300 tons Maintain positive drainage throughout construction. Include grading and drainage transitions, erosion protection, excavation, stabilization and restoration necessary for a complete drainage system. PAVING Native subgrade: final grading, moisture conditioning and compaction to 95% Standard Proctor to 8" depth – approximately 9,015 SY Tensar BX-1200 geogrid – approximately 9,015 SY Type A Grade 2 limestone base, 6" thick under/behind curb – approximately 2,000 SY Type A Grade 2 limestone base, 9.5" thick between curbs – approximately 7,015 SY MC-30 prime coat – approximately 7,015 SY Single-course surface treatment, AC-15P or CRS-2P with Grade 3 aggregate – approximately 7,015 SY Type D hot-mix asphaltic concrete, 2" thick – approximately 7,015 SY Concrete curb and gutter, 6"x24" and 4"x24" – approximately 4,503 LF Concrete intersection at entrance – approximately 4,465 SF Concrete valley gutters – approximately 928 SF Concrete sidewalks – approximately 1,651 SF Accessible curb ramps with truncated-dome detectable warnings – 6 EA Include pavement tie-ins, sawcutting, joints, reinforcement where detailed, preparation, compaction and restoration. ADDITIONAL REQUIREMENTS – NOT LIMITED TO BID SHEET ITEMS Contractor shall include work incidental to and necessary for completion of the applicable scope shown on the plans, including field verification of existing utilities and elevations, protection of existing facilities, pipe …
Owner: Spring green Victoria Estate Ventures, LLC · Project number: E27594.00 · Location: Victoria County, TX
Bids are due Friday, October 30, 2026 at 6:00 PM CDT.
Please provide pricing broken down by General, Site Preparation/Earthwork, Sanitary Sewer, Water, Drainage and Paving. Provide unit pricing where applicable, proposed construction duration/calendar days, assumptions, exclusions, lead times and proposal validity.
The scope is not limited to the items specifically listed in the Estimated Quantities & Bid Sheet. Include all incidental and related work shown or reasonably required by the construction drawings for a complete civil installation. Clearly identify exclusions, qualifications, alternates, lead times, construction duration and proposal validity. Special attention shall be given to work in or near the Energy Transfer pipeline easement and to all City of Victoria utility, testing, traffic-control, SWPPP and restoration requirements.
2 documents (plans, specifications and addenda) are posted on CIVCAST at https://app.civcast.com/bid-opportunities/projects/6ad8cdaa5f155c8646cd4408, where bidders also register as plan holders.
Reproduced from the official notice via CIVCAST Bid Opportunities. The agency's page is the one that counts.
Check before bidding
- Only 3 days left to prepare a bid.
Taken from the notice as published. BusyBids does not assess whether you meet a requirement - confirm anything that matters with the issuing agency.
Important dates
Add all to calendar| Event | Date and time | |
|---|---|---|
| Bid deadline3 days remaining - last confirmed 27 Oct | 30 October 2026, 6:00 PM CDT check | 3 days |
Times are shown in the agency's own zone. Confirm every deadline against the official notice.
Save this bid
We will remind you before it closes and tell you if the deadline moves. Free, no password, one click to stop.
We never share your address. No password needed.
Where this came from
Collected from CIVCAST Bid Opportunities, first seen 21 October 2026, last confirmed 27 October 2026.
The notice text above and every date and requirement are reproduced from the source. Confirm every deadline against the official notice before you bid.
Something wrong with this listing? Tell us.
We reproduce what the agency published. If we got it wrong we want to know - a wrong deadline can cost you a bid.
Similar open bids
-
Posted Oct 2 Checked today Special districtDue Oct 27, 1:00 PM CDT Closes today
-
Posted Sep 21 Checked today Special districtPre-bid meetingDue Oct 27, 2:00 PM CDT Closes today
-
Posted Sep 25 Checked today CityPre-bid meetingDue Oct 27, 2:00 PM CDT Closes today
-
Posted Oct 12 Checked today CityDue Oct 27, 2:00 PM CDT Closes today
-
Posted Oct 1 Last checked 9 Oct CountyDue Oct 27, 2:00 PM CDT Closes today
-
up to $500K estimated Posted Sep 25 Checked today CityMandatory site visitDue Oct 27, 2:00 PM CDT Closes today